Basic Info.
Application
High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type
Single & Three Phase Output
Principle of Work
Vector Control Transducer
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Universal Purpose
Brand
Our Own or Customers
Votalge Range
220V, 380V,440V,480V(-15%~20%)
Certificate
Ce & ISO & RoHS
Transport Package
Vacuum Package
Specification
Depends on KW
Product Description
Product Description
FC155 series frequency inverter has the following features:
Rich vector V/F control algorithm.
Optimized V/F control has better low speed stability, stronger low frequency torque output
capability and better dynamic response.
Smaller and more compact volume.
More abundant functions.
485 communications, external high precision PID, multi-speed and simple PLC, swing
frequency , fixed length and counting function.
Name Rule
FC155 Series Frequency Inverter
Table 2-1 Models and technical data of FC155 series
Model | Power Capacity (KVA) | Input Current (A) | Output Current (A) | Adaptable Motor |
---|
KW | HP |
---|
Single-phase 220V, 50/60Hz |
FC155-0R4GS2 | 1 | 5.4 | 2.3 | 0.4 | 0.5 |
FC155-R75GS2 | 1.5 | 8.2 | 4 | 0.75 | 1 |
FC155-1R5GS2 | 3 | 14 | 7 | 1.5 | 2 |
FC155-2R2GS2 | 4 | 23 | 9.6 | 2.2 | 3 |
Three-phase 220V, 50/60Hz |
FC155-0R4GT2 | 1.5 | 3.4 | 2.1 | 0.4 | 0.5 |
FC155-R75GT2 | 3 | 5 | 3.8 | 0.75 | 1 |
FC155-1R5GT2 | 4 | 5.8 | 5.1 | 1.5 | 2 |
FC155-2R2GT2 | 5.9 | 10.5 | 9 | 2.2 | 3 |
FC155-3R7GT2 | 8.9 | 14.6 | 13 | 3.7 | 5 |
FC155-5R5GT2 | 17 | 26 | 25 | 5.5 | 7.5 |
FC155-7R5GT2 | 21 | 35 | 32 | 7.5 | 10 |
FC155-011GT2 | 30 | 46.5 | 45 | 11 | 15 |
FC155-015GT2 | 40 | 62 | 60 | 15 | 20 |
FC155-018GT2 | 57 | 76 | 75 | 18.5 | 25 |
FC155-022GT2 | 69 | 92 | 91 | 22 | 30 |
FC155-030GT2 | 85 | 113 | 112 | 30 | 40 |
FC155-037GT2 | 114 | 157 | 150 | 37 | 50 |
FC155-045GT2 | 134 | 180 | 176 | 45 | 60 |
FC155-055GT2 | 160 | 214 | 210 | 55 | 75 |
FC155-075GT2 | 231 | 307 | 304 | 75 | 100 |
Three-phase 380V, 50/60Hz |
FC155-R75GT4 | - | 1.5 | 3.4 | 2.1 | 0.75 | 1 |
FC155-1R5GT4 | - | 3 | 5 | 3.8 | 1.5 | 2 |
FC155-2R2GT4 | - | 4 | 5.8 | 5.1 | 2.2 | 3 |
FC155-3R7GT4 | - | 5.9 | 10.5 | 9 | 3.7 | 5 |
FC155-5R5GT4 | FC155-5R5PT4 | 8.9 | 14.6 | 13 | 5.5 | 7.5 |
FC155-7R5GT4 | FC155-7R5PT4 | 11 | 20.5 | 17 | 7.5 | 10 |
FC155-011GT4 | FC155-011PT4 | 17 | 26 | 25 | 11 | 15 |
FC155-015GT4 | FC155-015PT4 | 21 | 35 | 32 | 15 | 20 |
FC155-018GT4 | FC155-018PT4 | 24 | 38.5 | 37 | 18.5 | 25 |
FC155-022GT4 | FC155-022PT4 | 30 | 46.5 | 45 | 22 | 30 |
FC155-030GT4 | FC155-030PT4 | 40 | 62 | 60 | 30 | 40 |
FC155-037GT4 | FC155-037PT4 | 57 | 76 | 75 | 37 | 50 |
FC155-045GT4 | FC155-045PT4 | 69 | 92 | 91 | 45 | 60 |
FC155-055GT4 | FC155-055PT4 | 85 | 113 | 112 | 55 | 75 |
FC155-075GT4 | FC155-075PT4 | 114 | 157 | 150 | 75 | 100 |
FC155-090GT4 | FC155-090PT4 | 134 | 180 | 176 | 90 | 125 |
FC155-110GT4 | FC155-110PT4 | 160 | 214 | 210 | 110 | 150 |
FC155-132GT4 | FC155-132PT4 | 192 | 256 | 253 | 132 | 175 |
FC155-160GT4 | FC155-160PT4 | 231 | 307 | 304 | 160 | 210 |
FC155-200GT4 | FC155-200PT4 | 250 | 385 | 377 | 200 | 260 |
FC155-220GT4 | FC155-220PT4 | 280 | 430 | 426 | 220 | 300 |
FC155-250GT4 | FC155-250PT4 | 355 | 468 | 465 | 250 | 350 |
FC155-280GT4 | FC155-280PT4 | 396 | 525 | 520 | 280 | 370 |
FC155-315GT4 | FC155-315PT4 | 445 | 590 | 585 | 315 | 420 |
FC155-355GT4 | FC155-355PT4 | 500 | 665 | 650 | 355 | 470 |
FC155-400GT4 | FC155-400PT4 | 565 | 785 | 725 | 400 | 530 |
FC155-450GT4 | FC155-450PT4 | 630 | 883 | 820 | 450 | 600 |
Technical Specifications
Technical specifications of FC155
Item | Specifications |
---|
Standard functions | Maximum frequency | 0~3200.00Hz |
Carrier frequency | 0.5-16 kHz(The carrier frequency is automatically adjusted based on the load features.) |
Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% |
Control mode | Sensor-less flux vector control (SFVC) Closed-loop vector control (CLVC) (+PG Card) Voltage/Frequency (V/F) control |
Startup torque | G type: 0.3Hz/150% (SFVC) ; 0 Hz/180% (CLVC) P type: 0.5Hz/100% |
Speed range | 1: 200 (SFVC) | 1:1000 (CLVC) |
Speed stability accuracy | ± 0.5% (SFVC) | ± 0.02% (CLVC) |
Torque control accuracy | ±5% (CLVC) |
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current P type: 60s for 120% of the rated current, 3s for 150% of the rated current |
Torque boost | Auto boost; Manual boost: 0.1%~30.0% |
V/F curve | Straight-line V/F curve Multi-point V/F curve N-powerV/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) |
V/F separation | Two types: complete separation; half separation |
Acceleration/deceleration curve | Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.00s~65000s |
Standard functions | DC braking | DC braking frequency: 0.00 Hz ~ maximum frequency Braking time: 0.0~100.0s Braking trigger current value: 0.0%~100.0% |
JOG control | JOG frequency range: 0.00Hz~50.00 Hz JOG acceleration/deceleration time: 0.00s~65000s |
Built-in PLC, multiple speeds | It realizes up to 16 speeds via the simple PLC function or combination of DI terminal states. |
Built-in PID | It realizes closed loop control system easily. |
Auto voltage regulation (AVR) | It can keep constant output voltage automatically when the mains voltage fluctuation. |
Overvoltage/ Over current stall control | The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage/over current. |
Rapid current limit function | It can auto limit running current of frequency inverter to avoid frequently tripping. |
Torque limit and control | (Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process. Torque control can be implemented in the VC mode. |
Individualized functions | High performance | Control of asynchronous motor is implemented through the high-performance current vector control technology. |
Instant power off not stop | The load feedback energy compensates the voltage reduction so that the frequency inverter can continue to run for a short time. |
Rapid current limit | To avoid frequently over current faults of the frequency inverter. |
Timing control | Time range: 0.0~6500.0 minutes |
Multiple communication protocols | Currently supports communication bus via Modbus-RTU and later will support PROFIBUS-DP, CANopen, etc. |
Motor overheat protection | The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100, PT1000) so as to realize motor overheat protection. |
Multiple encoder types | It supports incremental encoder and encoders such as differential encoder, open-collector encoder, resolver, UVW encoder, and SIN/ COS encoder. |
Advanced background software | It supports the operation of frequency inverter parameters and virtualoscillograph function, by which the state of frequency inverter can be monitored. |
Run | Running command giving | key panel Control terminals Serial communication port You can switch between these giving in various ways. |
Frequency giving | There are 10 kinds frequencygiving: digital setting, analog voltage setting, analog current setting, pulse setting, serial communication port setting, panel potentiometer, etc. You can switch between these giving in various ways. |
Auxiliary frequency giving | There are 10 kinds auxiliary frequency giving. It can implement tiny tuning of auxiliary frequency and frequency synthesis. |
Input terminal | Standard: 5 digital input (DI) terminals, one of which supports up to 100 kHz high-speed pulse input 2 analog input (AI) terminals, support 0V~10 V voltage input or 0 mA~20 mA current input Expanding capacity: 5 DI terminals 1 AI terminal supports -10V~10 V voltage input. |
Output terminal | Standard 1 high-speed pulse output terminal (open-collector) that supports 0-100 kHz square wave signal output 1 digital output (DO) terminal 1 relay output terminal 2 analog output (AO) terminals, support0 mA~20 mA current output or 0 V~10 V voltage output. Expanding capacity: 1 DO terminals 1 relay output terminals |
Display and operation on the key panel | LED display | It displays the parameters. |
Parameters copy | It can implement copy parameters function by PC software. |
Key locking and function selection | It can lock the keys partially or completely and define thefunction range of some keys so as to prevent misoperation. |
Protection mode | Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection, overheat protection and overload protection, etc. |
Environment | Installation location | Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude | Lower than 1000 m |
Ambient temperature | -10°C~ +40°C (derated if the ambient temperature is between 40°C and 50°C) |
Humidity | Less than 95%RH, without condensing |
Vibration | Less than 5.9 m/s2 (0.6 g) |
Storage temperature | -20°C ~ +60°C |
The housing type of the FC155 models is listed in the following table.
Voltage & Power Class | Housing Type |
Single-phase 220V |
0.4 - 2.2 Kw | Plastic housing |
Three-phase 220 V |
0.4 - 7.5 Kw | Plastic housing |
11 -75 Kw | Metal sheethousing |
Three-phase 380 V |
0.75 - 18.5 Kw | Plastic housing |
22 - 400 Kw | Metal sheet housing |
2.5.2 Appearance and Mounting Hole Dimension (mm) of FC155 Frequency Inverter
Table 2-3 Appearance and mounting hole dimension (mm) of FC155 frequency inverter
Model | Appearance and installing dimension(mm) | |
A | B | H | H1 | W | D | Φd |
Three-phase 380V |
FC155-R75G/1R5PT4 | 113 | 172 | 186 | - | 125 | 164 | ø5.0 | 2.0 |
FC155-1R5G/2R2PT4 |
FC155-2R2G/3R7PT4 |
FC155-3R7G/5R5PT4 | 148 | 236 | 248 | - | 160 | 183 | ø5.0 | 3.5 |
FC155-5R5G/7R5PT4 |
FC155-7R5G/011PT4 |
FC155-011G/015PT4 | 190 | 305 | 322 | - | 208 | 192 | ø6 | 6.2 |
FC155-015G/018PT4 |
FC155-018G/022PT4 | 230 | 440 | | 455 | 290 | 218 | ø7 | 16.2 |
FC155-022G/030PT4 |
FC155-030G/037PT4 |
FC155-037G/045PT4 | 230 | 540 | | 555 | 320 | 240 | ø10 | 30 |
FC155-045G/055PT4 |
FC155-055G/075PT4 | 320 | 610 | | 635 | 410 | 239 | ø12 | 45 |
FC155-075G/090PT4 |
FC155-090G/110PT4 | 320 | 630 | | 654 | 460 | 340 | ø12 | 65 |
FC155-110G/132PT4 |
FC155-132G/160PT4 | 320 | 856 | | 886 | 520 | 385 | ø13 | 105 |
FC155-160G/200PT4 |
FC155-200G/220PT4 |
FC155-220G/250PT4 | 500 | 1313 | | 1350 | 750 | 432 | ø13 | 240 |
FC155-250G/280PT4 |
FC155-280G/315PT4 |
FC155-315G/355PT4 | 500 | 1410 | | 1450 | 850 | 432 | ø13 | 300 |
Peripheral Devices Connection Diagram
Instructions of Main Circuit Peripheral Devices
Table 3-1 Main circuit peripheral devices use instructions
Parts Name | Installation Location | Function Description |
MCCB | Front of input circuit | The capacity of the circuit breaker shall be 1.5 to 2 times of the rated current of the inverter. The protect time of the circuit breaker shall fully consider the time features of the inverter overload protection. |
Residual-current circuit breaker(RCCB) | Front of input circuit | As the inverter output is the high-frequency pulse voltage, so that it will arise a high-frequency leakage current. Special leakage circuit breaker shall be used when installing leakage circuit breaker at the input side of the inverter. B type leakage circuit breaker is recommended, and the leakage current value shall be set as 300mA. |
Contactor | Between MCCB and input side of frequency inverter | Frequently open and close of contactor will cause inverter failure, so that the highest frequency for opening and closing of contactor shall be not exceeded than 10 times/min when braking resistor is used, to avoid the over-hot damage of braking resistor, please install thermal protection relay to do over-hot detection of braking resistor, to control the disconnection of the input contactor via touch points of the thermal protection relay. |
Input AC reactor or DC reactor | Input side of frequency inverter , near the inverter | 1. The inverter power supply capacity is more than 600kVA or 10 times of the power supply capacity. 2. If there is switch type reactive-load compensation capacitor or load with silicon control at the same power node, there will be high peak current flowing into input power circuit, causing the damage of the rectifier components. 3. When the voltage unbalance degree of the three-phase power supply of the inverter exceeds 3%, the rectifier components will be damaged. 4. It is required that the input power factor of inverter shall be higher than 90%. When the above situations occurred, install the AC reactor at the input side of inverter or DC reactor to the DC reactor terminal. |
Input noise filter | Input side of frequency inverter | To reduce the noise input from the power to the inverter or output from the inverter to the power. |
Thermal protection relay | Output side of frequency inverter | Although the inverter has motor overload protection function, when one inverter drives two or more motors or multi-pole motors, to prevent the motor over-temperature failure, thermal protection relay shall be installed between the inverter and each motor. |
Output filter | Output side of frequency inverter | When the output side of the inverter is connected with output filter, the conduction and radiation interference can be reduced. |
Output AC reactor | Between the output side of frequency inverter and motor, near the frequency inverter | When the cable connecting the inverter and the motor is longer than 100 meters, it is suggested to install AC output reactor to suppress the high-frequency oscillation to avoid the damage to motor insulation, large leakage current and frequent inverter protective action. |
Our Service:
1. Can I get some samples?
Yes, Sample order is available for quality check and market test .But you have to pay for it .
2. What's delivery time?
It usually takes about 3-5 working days for small order and 10-15 days for big order .
3. What's your payment terms?
We usually accept all kinds of payment terms .Such as T/T,L/C, Western Union.Cash.
4. What's your warranty terms?
We offer 24 months warranty time .
5. Do you have the products in stock?
Depends on your request ,We have standard models in stock. Some special products and big order will be newly produced according to your order .
6. Can I mix different power in one container .
Yes ,Different models can be mixed up in one container ,even one order .
7. How does your factory do the quality control?
Quality is priority ,we always attach the importance to quality control from the beginning to the end of the production .every product will be fully assembled and carefully tested before packing and shipping .
8. Can you sell spare parts ?
If you are using our products .we can sell spare parts to you . But we couldn't sell the half-finished products.
9.I would like to know if you have a partner for export?
Yes .We have the right to export and can sell electrical product all over the world..
10. Can you make the inverter and soft starter control boards (switchgear)?
Yes. We have a lot of experience to design frequency inverter and soft starter cabinet according to your request,and our factory can do soft starter by ourselves.
11.Can the inverter connect with computer?
Yes .All inverters have built-in RS485 port .and support Modbus communication protocol.
12.How can I trust you ?
Our company has been audited and approved ISO9001,CE.CCC. Assessment report will could be sent to you by e-mail. and we will take all the responsibility once problem during warranty time.
Address:
Building a, Guanghui Industry Park, Huangtian Road, Xixiang Town, Bao′an District, Shenzhen City, Guangdong Province, Shenzhen, Guangdong, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 14000, GMP
Company Introduction:
Founded in 1999, XIN FENG FU CHANG FA ELECTRONIC Co., Limited is not only a professional high-tech enterprise specializing in high-end printed PCB manufacturing, but also highly skilled in focusing on green energy of harmonic drive. Our factory covers an area of 53, 000 square meters, registered capital has reached 12 million yuan.
In PCB area, obtained ISO9001, ISO14001, RoHS and UL (e232205) certificates, our company is the one of the large and most advanced circuit board manufacturers in China. We introduced advanced automatic production equipment and sophisticated precision testing instruments from the USA, Japan, Hong Kong and Taiwan, providing a powerful guarantee for scale production and high quality. It has multi-layer/double-sided PCB department, HDI PCB department, flexible PCB/ rigid-flex PCB department. Four manufacturing centers and a supporting SMT production lines. Main business for PCB circuit board applications includes LED circuit board, power supply PCB, phone motherboard, electronic display, security system, computer...
In AC Drive area, we have obtained ISO9001: 2008 and CE certificate, we are highly skilled in focusing on green energy of harmonic drive, including high frequency inverter, low voltage inverter, and different variable frequency inverter for general purpose. As a council member of Inverter Branch of China Electric Appliance Industrial Association, all of our software and hardware are developed by its own D&R, and the main components are from top-brands in the world, e. g. IGBT from Infineon of Germany, capacitor from NCC of Japan, rectifier bridge from Microsemi, PCB board from TDK of Japan, and fan from NAIS of Taiwan and also NIDEC of Japan, MCU from DSP of IT in USA, MOS Tube from ST etc. Our products mainly serve for Equipment Manufacturing, Energy-saving&Environmental protection, and New energy field, and are widely used in elevator, crane, machine tool, metal products, wire and cable, plastic cement, printing packaging, textile chemical fiber, construction materials, metallurgy, colliery, civicism and auto industry.
With timely service and superior quality, we have gained high reputation for its applicability and reliability in these two industries, together with competitive price make us develop a word-wide market network and our products have been exported to southeast Asia, Russia, Europe, Pakistan and many other countries, and what we offer is not only products but also solutions and services to meet all customers′ needs.
Since more than a decade, XIN FENG FU CHANG FA is strived to become the best reliable supplier of automated products and PCB Boards, and committed to research and manufacture for developing into a large well-known supplier/manufacturer in worldwide. Our business philosophy is"customer-based, credit-oriented", our mission is to improve the industrial automation application, and our value is to establish a human-centric development platform.
A warm welcome is extended to visit our company when you are visiting China.